Cookie Img
Calitron Calibration
Home » Services » Patient Monitor Services » Patient Monitor Services

Patient Monitor Services

Patient Monitor Services
Patient Monitor Services
Service Code : CCL 1
Brand Name : CALITRON CALIBRATION LABORATORY

 

We are identified as one of the leading organizations, engaged in offering our clients Patient Monitor Services. Our patient monitoring portfolio provides actionable, care-specific information when and where it’s needed. Our range of patient monitors span care environments, patient acuity levels, and clinical requirements while supporting flexible care with portable, compact and specialized models. We are obligated to provide interfacing information and data necessary for monitoring. We offer Patient Monitor Services at cost effective rates.

Features:

  • Increase in mobility, connectivity and portability
  • Infrastructure management
  • User friendly interface

Technical Specifications for SimCube SC-5

Physical Dimensions

Size 3" x 3" x 3.5" (7.6cm X 7.6cm X 8.9cm)

Weight 2.5 Lbs

Power External A/C Adaptor (Output: 6VDC / 2amps, 2.1mm,

center positive connector) or

4 AA Batteries (with Battery Boost Option)

NIBP Connection Quick Disconnect, Female

ECG/Resp Connection 10 ECG snaps

IBP Connection Mini-DIN

Manometer

Range - 400 to + 400 mmHg

Precision 0.1 mmHg

Accuracy +/-1% of reading

User Interface

Single Button Operation

Operating Modes Adult NIBP

Neo NIBP

Hypertensive NIBP

Hypotensive NIBP

Manometer

Peak Detect

HR Seq. Alarm Test

ECG Pace ON

Arrhythmia Sequence

Heart Rate Sequence

Invasive BP Zero

Invasive BP 100, 200

Invasive BP Sequence

NIBP Adult Simulation

Simulated Pressure 120/80 (100) mmHg

Simulated Heart Rate 70 bpm

Simulated Pulse Volume 1 ml

NIBP Neonatal Simulation

Simulated Pressure 70/40 (55) mmHg

Simulated Heart Rate 95 bpm

Simulated Pulse Volume 0.5 ml

NIBP Hypertensive Simulation

Simulated Pressure 190/120 (150) mmHg

Simulated Heart Rate 70 bpm

Simulated Pulse Volume 1 ml

NIBP Hypotensive Simulation

Simulated Pressure 80/40 (60) mmHg

Simulated Heart Rate 70 bpm

Simulated Pulse Volume 1 ml

ECG Simulation

Isolated Yes

Synchronized with NIBP Yes

R Wave Size 1mV (lead I) +/- 5%

R Wave Width 35 ms

Wave Shape QRS wave

Connection 10 Snaps

Simulation Rates 70, 95, Asystole, Arrhythmia, Pacer, HR seq.

HR Sequence

30 seconds each of:

30, 60, 90, 120, 45, 160, and 220 bpm

Pacer Simulation

Isolated Yes

Synchronized with NIBP Yes

Pacer Size 3 mV

Pacer Width 1.2 ms

Respiration Simulation

Isolated Yes

Synchronized with NIBP Yes

Wave Shape Square Wave

Size 4 Ohm

Rate 35 bpm (47 bpm for neonatal)

Simulation rates 20, 40, Apnea, Sequence = 00, 30, 45, 60, 22, 30, 80, 110.

Arrhythmia Simulation

Cardiac failure sequence: ~ 90 seconds of normal beats

interspersed with PVCs and Runs, followed by ~20 seconds

of VTAC, followed by ~35 seconds of VFIB, concluding

with ~30 seconds of asystole.

Peak Detect

Precision 0.1mmHg

Invasive Blood Pressure Simulation

Isolated Yes

Synchronized with NIBP Yes

Excitation Voltage DC range = 3.3 to 5.7 AC range = 6.65 to 11.4p-p

Pressure range 0-250 mmHg

Simulated Pressure accuracy +/- 1 mmHg

Wiring + Excit = pin 1, - Excit = pin 4, + Sig = pin 3, -Sig = pin 6

Simulation rates Dynamic = 120/80, 70/40, 190/120.

Static = 0, 100, 200.

Step = 0,25,50,100,150,200, 250

Environmental

Voltage Range 100-240 VAC, 50-60 Hz

 



 FOR COMMERCIAL OFFER

PLEASE CONTACT-9881491483 

 

 

 


CALITRON CALIBRATION LABORATORY

Contact Us

( *represents compulsory fields )

Tips on getting accurate quotes. Please include product name, order quantity, usage, special requests if any in your inquiry.



Back to top